System Parameters - Web Services
Use the Web Services tab to configure the addresses of the web services used in Communicare.
Security certificates for the web services are maintained on Organisation Parameters - Certificates.
Pane | Parameters & Description |
---|---|
ADHA Provider Directory Service (PDS) | If
required, specify information for the ADHA PDS:
Tip: On the System tab, also
enable the Address Book Integration - ADHA
PDS module. |
Healthcare Identifiers (HI) Service | Set Enable HI Service and enter the web
service address of the HI Service, either:
|
Electronic Transfer of Prescriptions (ETP) | The path to the eRx Adapter software that enables ETP, entered by Communicare when this module is enabled. |
Enterprise Provider Directory (EPD) Service | If required, specify the web service address of the EPD:
|
Communicare Web Service | Specify the address of the Communicare web service. For example, https://webservices.communicaresystems.com.au:9000 |
My Health Record Service | Specify the web service address of the My Health Record Service, either:
|
Real-Time Prescription Monitoring (RTPM) Service | Specify the address of the Safescript web service:
|
EMPI Search | Specify the web service address of the EMPI search service. |
Clinical Decision Support (CDS) | To use the
CDS service to link
to the online MIMS database for condition and pregnancy interaction
checking when prescribing instead of the locally installed MIMS
database, set Enable Decision Support and add
information to the following fields:
Note: If the CDS service is
enabled and you are working offline, condition and pregnancy
interaction checking won't be available. The default timeout for
calls to the CDS server is 2000 milliseconds. If you would like this
extended, contact Communicare Support.Tip: If you don't want pregnancy or condition interaction
warnings displayed when prescribing, ask Communicare Support to disable
them. |
Services Australia |
In V21.3 and later, settings required to connect to Service
Australia's web services. Set Enable Services
Australia to use these settings.
Tip: The default timeout for calls
to Services Australia is 5000 milliseconds. If you would like
this changed, contact Communicare Support.
|
SNOMED Terminology | Specify the addresses of the SNOMED Terminology database:
|
National Cancer Screening Register (NCSR) | Specify your organisation's National Cancer Screening Register
(NCSR) registration details:
Tip: Before you can specify NCSR settings, on the
System tab, first enable the
NCSR Integration
module. |